- Products
- Ground Fault Monitoring, Grounded

LINETRAXX® RCMS460-D
- Multi-channel ground-fault monitoring relay for grounded and high-resistance-grounded AC/DC systems
- Monitor up to twelve separate channels with individually adjustable alarm trip values
- Digital display with real-time readings and on-board menu
- Harmonics analysis and selectable filtering options
- Contact outputs and compatibility with Ethernet and Modbus communication gateways
The RCMS460 series provides ground-fault monitoring for up to twelve separate systems or channels in grounded and high-resistance grounded, AC/DC, single-phase or three-phase systems. The RCMS460 is also compatible with systems that contain power conversion equipment, such as variable frequency drives.
Each channel has an independently adjustable trip value. For AC systems, the trip value is adjustable from 6 mA to 20 A. For DC and mixed AC/DC systems, the trip value is adjustable from 10 mA to 10 A. Each channel is individually monitored with a connected current transformer, available in a wide range of sizes, shapes, and core types.
Three separate time delays are available - a pickup delay, startup delay, and delay on reset. Advanced harmonics analysis and filtering options allow for tailoring use to specific application requirements.
The on-board LCD display shows a detailed system overview, including a chart showing measured ground-fault current in real-time, individual alarm messages for each channel, and an easy-to-use menu for adjusting settings. Advanced harmonics analysis and filtering options allow for tailoring the relay's monitoring capabilities to specific application requirements.
Two configurable Form-C (SPDT) outputs trigger on alarm activation. The RCMS460 is compatible with Bender's communication gateways for connecting to Ethernet and Modbus networks.
- Features
- Applications
- Accessories
- Ordering information
- Downloads
- Multi-channel ground-fault protection for solidly and high-resistance grounded AC and DC systems, single-phase and three-phase
- Meets or exceeds code requirements for ground-fault detection on grounded AC and DC systems where applicable
- Individually monitor up to twelve systems / circuits from one relay
- Detailed digital display showing measured values in real-time
- Individually adjustable trip values, as low as 6 mA and as high as 20 A
- Connects to current transformers available in a wide range of sizes, shapes, and core types
- On-board test and reset button with connections for external activation
- Adjustable time delays (pickup, startup, on reset)
- Latching or non-latching operation
- Two Form-C (SPDT) alarm outputs, operating normally energized (failsafe) or de-energized (non-failsafe)
- Compatible with Bender's communication gateways for connection to Ethernet or Modbus networks
- Ground fault monitoring on grounded and high-resistance grounded AC/DC systems
- Systems with variable frequency drives, inverters, and other power conversion equipment
- General purpose DC systems, per NEC 250.167(B)
- General power distribution
- Motors and motor control centers
- Control systems
- Heat trace systems, per NEC 427.22 and CEC 62-116
- Solar arrays, per NEC 690.41(B) (2017 edition), NEC 690.5 (2014 edition), and CEC 64-064(4)
- Energy storage systems
Optional accessories for LINETRAXX® RCMS460-D
Part No. | Opening | Shape and Type | Ordering No. |
---|---|---|---|
W1-S35 | 1.35" (35mm) | circular, solid | B911731 |
W2-S70 | 2.75" (70mm) | circular, solid | B911732 |
W3-S105 | 4.1" (105mm) | circular, solid | B911733 |
W4-S140 | 5.5" (140mm) | circular, solid | B911734 |
W5-S210 | 8.25" (210mm) | circular,solid | B911735 |
WR70x175S | 2.75"x6.9" (70x175mm) | rectangular, solid | B911738 |
WR115x305S | 4.5"x12" (115x305mm) | rectangular, solid | B911739 |
WR150x350S | 5.9"x13.8" (150x350mm) | rectangular, solid | B911740 |
WR200x500S | 7.9"x19.7" (200x500mm) | rectangular, solid | B911763 |
WS20x30 | 0.75"x1.2" (20x30mm) | rectangular, split-core | B98080601 |
WS50x80 | 2"x3.1" (50x80mm) | rectangular, split-core | B98080603 |
WS80x120 | 3.1"x4.7" (80x120mm) | rectangular, split-core | B98080606 |
AC/DC current transformers
Part No. | Opening | Shape | Ordering No. |
---|---|---|---|
W20AB | 0.78" (20mm) | circular | B98080008 |
W35AB | 1.35" (35mm) | circular | B98080016 |
W60AB | 2.36" (60mm) | circular | B98080026 |
W120AB | 4.7" (120mm) | circular | B98080041 |
W210AB | 8.25" (210mm) | circular | B98080040 |
Power supply for use with RCMS and WAB series current transformers
Part No. | Description | Ordering No. |
---|---|---|
AN420-2 | Power supply for up to six WAB series current transformers | B94053100 |
Connection cable for use with RCMS and WAB series current transformers
Part No. | Length | Ordering No. |
---|---|---|
WXS-100 | 3' (1m) | B511100028 |
WXS-250 | 8' (2.5m) | B511100029 |
WXS-500 | 16' (5m) | B511100030 |
WXS-1000 | 32' (10m) | B511100027 |
WXS-1500 | 50' (15m) | B511100035 |
Communication gateways
Part No. | Description | Ordering No. |
---|---|---|
COM465IP | Ethernet and Modbus gateway | B95061065 |
CP700 | Ethernet and Modbus gateway and HMI | B95061030 |
Variants of LINETRAXX® RCMS460-D
Part No. | Supply Voltage | Output Contacts | Ordering No. |
---|---|---|---|
RCMS460-D-1 | 16-72 VAC (42-460 Hz), 16-94 VDC | 2 Form-C | B94053001 |
RCMS460-D-2 | 70-276 VAC (42-460 Hz), 70-276 VDC | 2 Form-C | B94053002 |
Downloads for LINETRAXX® RCMS460-D
Category | Product | Language | Size | Download |
---|