- Products
- Neutral Grounding Resistance Monitoring
- Neutral Grounding Resistance Monitoring

LINETRAXX® NGRM700
The NGRM700 Neutral Grounding Resistor Monitor detects grounding-resistor failures and ground faults and monitors line voltages. It is intended for use in high-resistance grounded commercial and industrial power systems. It is an advanced device that allows monitoring of :
- Current through the neutral-grounding resistor (NGR)
- Voltage between the transformer or generator neutral point and ground (voltage drop across the NGR)
- NGR failure (open and short), including failure of connections between neutral and ground
- Line-to-line and line-to-ground voltages
The NGRM500 can display the measured values, including current and voltage harmonics on the human machine interface (HMI). Users are able to select filters for ground-fault current and NGR voltage to prevent nuisance operation in noisy applications. A benefit to many users is the multilingual user interface that allows the comfort of reading values and programming in your native language.
It is designed for easy retrofit with a panel mountable human-machine interface (HMI). If preferred, the relay can easily be programmed via the built-in webserver. NGRM700’s can easily connect to a supervisory system with Modbus TCP/IP or RTU communications.
For generator or transformer grounding applications at extreme altitudes, the NGRM700 features a 5,000 m above sea level capability.
It is an ideal solution that is easy to retrofit into existing HRG applications or factory-install in new HRG packages. Capabilities extend to 25 kV and up to 100 A.
The NGRM700 allows the user to meet Canadian requirements. It can be used to perform the functions required by Rule 10-302, Use of Impedance Grounded Systems, of the CE Code, C22.1-21, Section 10, Grounding and Bonding.
- Features
- Accessories
- Ordering information
- Downloads
- Determination of RNGR with passive and active measurement methods
- Continuous monitoring of the RNGR even if the installation is de-energized
- Alarm or trip on ground fault
- Monitoring of the current INGR
- Monitoring of the voltage UNGR
- Phase-to-ground fault indication (optional; up to 690 V direct coupling, otherwise via potential transformers)
- Ethernet communication
- Web server
- Language selection (German, English GB and US, Spanish, French)
- Test button (internal, external) with/without tripping
- FFT analysis of the measuring signals
- Pulser for manual ground fault location
- Relay for detection of ground faults and resistor faults
- Relay for shutdown of the installation after a configurable time
- Can be combined with RCMS… for automatic shutdown of feeders
- Graphical user interface
- Wide supply voltage range (24 to 240 VAC/VDC)
- Range of use up to 5000 m AMSL
- Fault/history memory
- Analog output of measured values (0…10 V, 4…20 mA, etc., selectable parameters)
- Detachable HMI for door mounting
- Password protection
- Tripping on RMS, fundamental component signal or harmonics
- Detection of AC and DC ground faults
Optional accessories for LINETRAXX® NGRM700
Voltage Usys | Type | Art. No. |
---|---|---|
400…690 V | CD1000 | B98039010 |
400…1000 V | CD1000-2 | B98039053 |
1000…4200 V | CD5000 | B98039011 |
4300…14550 V | CD14400 | B98039054 |
14551…25000 V | CD25000 | B98039055 |
Measuring current transformer
Voltage/Current | Type | Art. No. |
---|---|---|
AC up to 25 A | W20 W35 W60 W0-S20 W1-S35 W2-S70 | B98080003 B98080010 B98080018 B911787 B911731 B911732 |
AC/DC up to 10 A | CTUB103-CTBC35 | B78120030 |
AC/DC up to 25 A | CTUB103-CTBC60 CTUB103-CTBC120 | B78120031 B78120032 |
Voltage supply for measuring current transformers CTUB103…
Type | max. connected measuring current transformers | Art. No. |
---|---|---|
STEP-PS/1 AC/24 DC/0.5 | 2 | B94053110 |
STEP-PS/1 AC/24 DC/1.75 | 7 | B94053111 |
STEP-PS/1 AC/24 DC/4.2 | 17 | B94053112 |
Clamp - Included with NGRM700
Name | Type | Art. No. |
---|---|---|
FP200-NGRM clamp (set of 2) | Metal screw | B91067907 |
Variants of LINETRAXX® NGRM700
Type | Supply voltage US/Frequency range Hz | Art. No. |
---|---|---|
NGRM700 | AC 24…240 V, 40…70 Hz DC 24…240 V | B94013700 |
Accessory for FP200-NGRM: Transparent front cover 144x72 (for IP65)* | B98060005 |
The degree of protection IP65 applies only to the user interface FP200-NGRM when using the front cover. The degree of protection for the complete device is still IP30.
Downloads for LINETRAXX® NGRM700
Category | Product | Language | Size | Download |
---|