Mon Jul 16 23:50:50 2018
Mon Jul 16 23:50:51 2018
ISOMETER® isoLR275 con AGH-LR

ISOMETER® isoLR275 con AGH-LR

El ISOMETER isoLR275 con el acoplador AGH-LR vigila la resistencia del aislamiento. Es de aplicación universal en sistemas 3(N) AC-, AC/DC- y DC. EI los sistemas AC también pueden existir equipos con componente de corriente continua (p.ej. rectificadores, convertidores, motores de continua regulados por tiristores). La adaptación a la capacidad de red es automática. Para acoplar al margen de tensión nominal se debe utilizar el acoplador AGH-LR que se incluye en el suministro. El isoLR275 puede operar con otros componentes del bus BMS.

  • Características
  • Aplicaciones
  • Accesorios
  • Información de pedido
  • Descargas
  • isoLR275
  • ISOMETER® for IT AC systems with galvanically connected rectifiers or converters and for IT DC systems (IT = unearthed systems)
  • Particularly suited for monitoring electrical installations with a low level of resistance
  • isoLR275 is always operated in conjunction with AGH-LR
  • Automatic adaptation to the existing system leakage capacitance
  • AMPPlus measurement method (European Patent: EP 0 654 673 B1)
  • Choice of measurement methods to meet different requirements
  • Two separately adjustable response ranges of 0.2 kΩ…100 kΩ each (Alarm 1, Alarm 2)
  • Two-line LC display
  • Automatic device self test
  • Memory with real-time clock to store alarm messages with date and time stamp
  • BMS interface (Bender Measuring Device Interface) for communication with other Bender devices (RS-485 galvanically isolated)
  • Internal disconnection of the ISOMETER® from the IT system to be monitored (via control signal; terminals F1/F2), e.g. if several ISOMETER®s are interconnected
  • Current output 0(4…20 mA (electrically isolated) in relation to the insulation value measured in the system
  • AGH-LR
  • Coupling device required for ISOMETER® isoLR275
  • Nominal voltage range AC 0…793 V and DC 0…1100 V
  • DIN rail mounting
  • AC, DC or AC/DC main circuits
  • IT systems with directly connected inverters
  • IT systems with high system leakage capacitances of up to 500 μF
  • IT systems with high but slow voltage fluctuations
  • Systems including switched-mode power supplies
  • Coupled IT systems

 

Variantes de ISOMETER® isoLR275 con AGH-LR


TypeNominal system voltage UnSupply voltage USArt. No.
isoLR275-327 + AGH-LR-3

consisting of:
isoLR275-327
AGH-LR
3(N) AC 0…793 V / DC 0…1100 VDC 19,2…72 VB91065702W


B91065700W
B98039022W
isoLR275-335 + AGH-LR

consisting of:
isoLR275-335
AGH-LR-3
3(N)AC 0…793 V / DC 0…1100 VAC 88…264 / DC 77…286 VB91065703W


B91065701W
B98039022W

Descargas para ISOMETER® isoLR275 con AGH-LR

Categoría

Idioma

Categoría Producto Idioma Fecha Tamaño Descarga