Industria del automóvil

High availability in the automotive industry

The automotive industry is one of the driving forces behind the overall economy in America. Any production downtime must be prevented at all costs. Potential electrical faults must be recognized early in order to prevent the system shutting down. Bender fault current monitoring devices or Bender ISOMETER®s master this role excellently and comply with all the necessary standards.

Request advice

Downloads

NameCategorySizeLanguageTimestampD-/B-Number
Product Overview ISOMETER®/ISOSCAN® Product Overviews 5.3 MB EN2024/02/1616.02.2024
Product Overview - Residual Current Monitoring Product Overviews 6.2 MB EN2023/11/0909.11.2023
Electrical Safety in Control and Auxiliary Circuits Technical Article 632.6 KB EN2019/05/1313.05.2019

Products

Ground-Fault Monitoring, Ungrounded

ISOMETER® iso685…
ISOMETER® iso685 Series

Ground-fault detector for ungrounded AC/DC systems

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D Blindspot®

Multi-channel AC/DC ground-fault monitor

LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D Blindspot®

Multi-channel AC/DC ground-fault monitor with individual relay outputs

LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor

LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor with one alarm contact per channel

Current Transformers

LINETRAXX® CTUB100 Series

AC/DC sensitive measuring current transformer (Type B)

Ground-Fault Monitoring, Ungrounded

ISOMETER® iso685…
ISOMETER® iso685 Series

Ground-fault detector for ungrounded AC/DC systems

Details

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

Details
LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D Blindspot®

Multi-channel AC/DC ground-fault monitor

Details
LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D Blindspot®

Multi-channel AC/DC ground-fault monitor with individual relay outputs

Details
LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor

Details
LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor with one alarm contact per channel

Details

Current Transformers

LINETRAXX® CTUB100 Series

AC/DC sensitive measuring current transformer (Type B)

Details

Standards

EN 61557-8

Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 8: Isolationsüberwachungsgeräte für IT-Systeme

EN 61557-9

Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 9: Einrichtungen zur Isolationsfehlersuche in IT-Systemen

EN 61557-15

Elektrische Sicherheit in Niederspannungsnetzen bis 1000 V AC und 1500 V DC - Geräte zum Prüfen, Messen oder Steuern von Schutzsystemen - Teil 15: Anforderungen an die funktionale Sicherheit von Isolationssteuergeräten in IT-Systemen und Geräten zur Erkennung von Isolationsfehlern in IT-Systemen

IEC 60204-1

Safety of machinery - Electrical equipment of machines - Part 1: General requirements

Accionamiento y cintas de transporte

Do you have any questions?

Please contact us! We are here to help.

Contact form