Locomotives and railcars need reliable and safe electrical power. The power for this is produced using a diesel generator on board or fed in to the vehicle from above from an overhead line or third rail. These drive systems on board the locomotives or railcars are normally ungrounded and therefore need to be safeguarded by means of a special ground-fault monitoring device. Bender ground-fault monitoring devices come in a rail RW variant to meet the specific requirements in terms of shock, vibration and temperature-resistance. Grounded power supplies can be protected via residual current monitors and voltage relays.
The rail cars in passenger trains and refrigerated rail cars for freight transport, for example, need separate power supplies. Bender can detect faults very early and quickly pinpoint them using ground-fault location devices for grounded and ungrounded applications. This reduces the potential risk for passengers, crew and equipment and saves valuable maintenance and repair time.
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
Power Quality/Measuring and monitoring relays | Product Overviews | 2.7 MB | EN | 2022/05/2525.05.2022 | |
Product Overview ISOMETER®/ISOSCAN® | Product Overviews | 5.3 MB | EN | 2024/02/1616.02.2024 | |
Product Overview - Residual Current Monitoring | Product Overviews | 6.2 MB | EN | 2023/11/0909.11.2023 | |
Railway Technology | Market Segment Brochures | 5.5 MB | EN | 2023/11/1313.11.2023 | |
Insulation Fault Location - Planning and Setup | Technical Article | 112.4 KB | EN | 2019/05/1313.05.2019 | |
Why the IT System is Often the Best Choice for Power Supply Systems of All Types | Technical Article | 3.0 MB | EN | 2019/07/1111.07.2019 | |
Predict and Protect - Signal Power Fault Detection Systems | Market Segment Brochures | 1.7 MB | EN | 2019/05/1313.05.2019 |
Products
Ground-fault monitoring device for railway applications up to AC/DC 440 V
Ground-fault monitoring device tailored to the requirements of railway rolling stock applications
Ground-fault location module for ungrounded AC/DC systems
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
Undervoltage/overvoltage relay for monitoring three-phase AC systems (window discriminator function)
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Ground-fault monitoring device for railway applications up to AC/DC 440 V
Ground-fault monitoring device tailored to the requirements of railway rolling stock applications
Ground-fault location module for ungrounded AC/DC systems
- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.
Undervoltage/overvoltage relay for monitoring three-phase AC systems (window discriminator function)
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Bahnanwendungen – Elektromagnetische Verträglichkeit Teil 3-2: Bahnfahrzeuge – Geräte
Bahnanwendungen Elektronische Einrichtungen auf Bahnfahrzeugen
Bahnanwendungen - Allgemeine Bau- und Schutzbestimmungen - Zusätzliche Anforderungen
Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 8: Isolationsüberwachungsgeräte für IT-Systeme
Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 9: Einrichtungen zur Isolationsfehlersuche in IT-Systemen