Puertos

Making ports electrically safe

Gantry cranes

Safely lifting loads and controlling cranes

Bender works in close cooperation with the manufacturers of gantry crane systems to optimize protection against electrical faults and guarantee the safety of the operating personnel. Ground-fault monitoring - Insulation monitoring or residual current monitoring - ensure high levels of safety and availability.

 

Request advice

Terminals

A high level of fire and personnel protection at the terminal

By means of ground-fault monitoring, Bender ensures the highest possible level of safety for people and systems and therefore guarantees a high level of system availability during embarking and disembarking or rather loading and unloading.

 

Request advice

Marinas

Mitigate risks of electric shock drowning

Today's recreational marinas are filled with potential electric hazards, such as refrigerators, lighting, and electric boat motors. Ground faults are a leading cause of death, injury, and equipment damage in marinas. Fault current leaking to the water creates a risk of boat corrosion and electric shock drowning (ESD) for people swimming in the water.

Bender's MarinaGuard is the result of years of direct involvement with the marina industry. Continuous monitoring for ground faults helps mitigate the risks to people, boats, and equipment - while providing a simple, streamlined system for technicians and harbor owners to use.

 

Request advice

Downloads

NameCategorySizeLanguageTimestampD-/B-Number
Product Overview ISOMETER®/ISOSCAN® Product Overviews 5.3 MB EN2024/02/1616.02.2024
Product Overview - Residual Current Monitoring Product Overviews 6.2 MB EN2023/11/0909.11.2023
Electrical safety costs little Market Segment Brochures 6.2 MB EN2024/02/2727.02.2024
Marinas and Shore Power (US) Market Segment Brochures 3.2 MB EN2023/05/0101.05.2023
Megayacht - Residual current monitoring in the luxury segment Market Segment Brochures 1.1 MB EN2024/02/2222.02.2024

Products

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D Blindspot®

Multi-channel AC/DC ground-fault monitor

LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor

LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D Blindspot®

Multi-channel AC/DC ground-fault monitor with individual relay outputs

LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor with one alarm contact per channel

Resistance Grounded Systems (HRG/LRG)

LINETRAXX® NGRM700

Monitor for use in high-resistance grounded systems

Current Transformers

LINETRAXX® CTUB100 Series

AC/DC sensitive measuring current transformer (Type B)

Ground-Fault Monitoring, Ungrounded

ISOMETER® iso685…
ISOMETER® iso685 Series

Ground-fault detector for ungrounded AC/DC systems

Ground-Fault Monitoring for Grounded Systems

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

Details
LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D Blindspot®

Multi-channel AC/DC ground-fault monitor

Details
LINETRAXX® RCMS460-L
LINETRAXX® RCMS460-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor

Details
LINETRAXX® RCMS490-D
LINETRAXX® RCMS490-D Blindspot®

Multi-channel AC/DC ground-fault monitor with individual relay outputs

Details
LINETRAXX® RCMS490-L
LINETRAXX® RCMS490-L Blindspot®

Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor with one alarm contact per channel

Details

Resistance Grounded Systems (HRG/LRG)

LINETRAXX® NGRM700

Monitor for use in high-resistance grounded systems

Details

Current Transformers

LINETRAXX® CTUB100 Series

AC/DC sensitive measuring current transformer (Type B)

Details

Ground-Fault Monitoring, Ungrounded

ISOMETER® iso685…
ISOMETER® iso685 Series

Ground-fault detector for ungrounded AC/DC systems

Details

Standards

NEC 555.3
CSA 22.1 Part 1 (CE Code) 78-052
DIN IEC/TS 61439-7

Niederspannungs-Schaltgerätekombinationen - Teil 7: Schaltgerätekombinationen für bestimmte Anwendungen wie Marinas, Campingplätze, Marktplätze, Ladestationen für Elektrofahrzeuge 

EN 61557-8

Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 8: Isolationsüberwachungsgeräte für IT-Systeme

EN 61557-9

Elektrische Sicherheit in Niederspannungsnetzen bis AC 1 000 V und DC 1 500 V – Geräte zum Prüfen, Messen oder Überwachen von Schutzmaßnahmen - Teil 9: Einrichtungen zur Isolationsfehlersuche in IT-Systemen

EN 61557-15

Elektrische Sicherheit in Niederspannungsnetzen bis 1000 V AC und 1500 V DC - Geräte zum Prüfen, Messen oder Steuern von Schutzsystemen - Teil 15: Anforderungen an die funktionale Sicherheit von Isolationssteuergeräten in IT-Systemen und Geräten zur Erkennung von Isolationsfehlern in IT-Systemen

Accionamiento y cintas de transporte

Do you have any questions?

Please contact us! We are here to help.

Contact form