The RCMA423 monitors for ground-fault current in solidly-grounded and high-resistance-grounded AC/DC (single-phase or three-phase) systems. The RCMA423 is also compatible with systems that contain power conversion equipment, such as variable frequency drives and inverters.
The pickup value is adjustable from 30 mA to 3 A (for a lower pickup value, refer to RCMA420 series). A separately configurable pre-warning alarm is also available. Three separately adjustable time delays are included - a pickup delay, startup delay, and delay on reset.
The RCMA423 provides an accurate, RMS value. Measurements are displayed in real-time via the device's on-board digital display. All device are configured using the display and push buttons. Two Form-C (SPDT) relay outputs are separately configurable to trigger on pre-warning or main alarms.
A single current transformer connects to the RCMA423 for measuring ground-fault current. A wide range of sizes are available.
The RCMA423 monitors for ground-fault current in solidly-grounded and high-resistance-grounded AC/DC (single-phase or three-phase) systems. The RCMA423 is also compatible with systems that contain power conversion equipment, such as variable frequency drives and inverters.
The pickup value is adjustable from 30 mA to 3 A (for a lower pickup value, refer to RCMA420 series). A separately configurable pre-warning alarm is also available. Three separately adjustable time delays are included - a pickup delay, startup delay, and delay on reset.
The RCMA423 provides an accurate, RMS value. Measurements are displayed in real-time via the device's on-board digital display. All device are configured using the display and push buttons. Two Form-C (SPDT) relay outputs are separately configurable to trigger on pre-warning or main alarms.
A single current transformer connects to the RCMA423 for measuring ground-fault current. A wide range of sizes are available.
Part No. | Supply Voltage | Ordering No. |
---|---|---|
RCMA423-D-1 | 16-72 VAC (42-460 Hz), 9.6-94 VDC | B94043023 |
RCMA423-D-2 | 70-300 VAC (42-460 Hz), 70-300 VDC | B94043025 |
Connection cable for use with RCMA420/423 and CTUB100 series current transformers
Part No. | Length | Ordering No. |
---|---|---|
CTX-100 | 3' (1m) | B98110080 |
CTX-250 | 8' (2.5m) | B98110081 |
CTX-500 | 16' (5m) | B98110082 |
CTX-1000 | 32' (10m) | B98110083 |
Enclosure mountings
Part No. | Ordering No. |
---|---|
XM420 | B990994 |
XM460 | B990995 |
XM490 | B990996 |
AC/DC current transformers
Part No. | Opening | Shape and Type | Ordering No. |
---|---|---|---|
CTUB101-CTBC20 | 0.78" (20mm) | circular, solid | B78120010 |
CTUB101-CTBC20P | 0.78" (20mm) | circular, solid | B78120020 |
CTUB101-CTBC35 | 1.35" (35mm) | circular, solid | B78120012 |
CTUB101-CTBC35P | 1.35" (35mm) | circular, solid | B78120022 |
CTUB101-CTBC60 | 2.4" (60mm) | circular, solid | B78120014 |
CTUB101-CTBC60P | 2.4" (60mm) | circular, solid | B78120024 |
CTUB101-CTBC120 | 4.7" (120mm) | circular, solid | B78120016 |
CTUB101-CTBC120P | 4.7" (120mm) | circular, solid | B78120026 |
CTUB101-CTBC210 | 8.25" (210mm) | circular, solid | B78120018 |
CTUB101-CTBC210P | 8.25" (210mm) | circular, solid | B78120028 |
Category | Name | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
CE Declarations of Conformity | RCMA42x | 88.7 KB | 2022/08/12 06:17:2512.08.2022 06:17:25 | ||
Manuals | RCMA423 | 1.7 MB | EN | 2021/05/07 10:08:2707.05.2021 10:08:27 | D00063 |
Datasheets | RCMA423 | 332.7 KB | EN | 2020/01/10 10:35:0310.01.2020 10:35:03 | D00063 |
Quickstarts | RCMA423 | 510.8 KB | EN | 2023/11/16 06:23:3616.11.2023 06:23:36 | D00063 |
Datasheets | XM420 interface options | 223.5 KB | EN | 2019/05/13 10:31:3613.05.2019 10:31:36 | D00051 |
Technical Information | Changed variants of relays from goldplated to silver-plated contacts | 166.3 KB | EN | 2022/06/27 09:03:0827.06.2022 09:03:08 |